Adelanto – Chevron – USA

Adelanto – Chevron – USA

Context

CHEVRON owns and operates a large quantity of gas stations in Southern California.

In accordance with their general environmental policies, as well as California State regulations, those gas stations need to be cleaned-up and put in accordance with current legislation.

Therefore, CHEVRON has remediated over 150 gas stations in Southern California in the last 10 years, where the TPH contaminated soil was sent for thermal treatment to the delanto (CA) facility, owned and operated by Deep Green / Haemers Technologies.

Equipment

Contaminated soils were processed by a counter flow, direct fired LTDU (Low Temperature Desorption Unit)with nominal capacity of 70 tons (US) per hour.

The equipment train included a pre-screener, belt scale conveyor, rotary dryer, fabric filter baghouse, thermal oxidizer, soil moisturizer, and radial stacker. Natural Gas was used as process fuel.

This project was designed and executed by the current Haemers Technologies team, when they worked within the legal entity L&C SA (formerly Deep Green SA), which belongs to the Haemers Technologies group.

Key Data

Contaminants
TPH

Max. Concentration
15.000

Volume
187.500

Tonnage
300.000

Treatment Targets
<50

Location
Adelanto – USA

Future Use
Industrial

Client
Exxon Mobil

Date
2004

Skip to content